BNC-2110 Installation Guide 10 ni.com
Figure 5. Connecting PFI 8 to USER 2 BNC
The designated space below each USER <1..2> BNC is for marking or labeling signal names.
Specifications
This section lists the specifications of the BNC-2110. These specifications are typical at 25 °C unless
otherwise specified.
Note Refer to your DAQ device documentation for specifications about analog input, analog output,
trigger/counter, and digital and timing I/O signals.
Physical
Dimensions ............................................................19.05 cm × 10.48 cm × 3.51 cm
(7.5 in. × 4.125 in. × 1.38 in.)
Weight ....................................................................798 g (1 lb 12.1 oz)
BNC connectors .....................................................15
Spring terminal block.............................................30 positions
Wire gauge .............................................................28–16 AWG wire
I/O connector .........................................................68-pin SCSI male connector
Environment
Operating temperature ...........................................0 to 70 °C
Storage temperature ...............................................–55 to 125 °C
Relative humidity...................................................5 to 90%, noncondensing
BNC Cable
PFI 8
Signal
Internal Connection
D GND
DIGITAL AND TIMING I/O
Spring Terminal Block
PFI 9/P2.1
PFI 8/P2.0
PFI 7/P1.7
PFI 6/P1.6
PFI 5/P1.5
PFI 4/P1.4
PFI 3/P1.3
PFI 2/P1.2
PFI 1/P1.1
D GND
USER 2
PFI 14/P2.6
+5V
+5V
D GND
P0.7
P0.6
P0.5
P0.4
P0.3
P0.2
P0.1
P0.0
PFI 13/P2.5
D GND
USER 1
PFI 11/P2.3
PFI 10/P2.2
AI SENSE
AI GND